Integra Metering AG (formerly Aquametro)

Ventes Integra Metering AG (formerly Aquametro) dans France

Economisez vos dépenses lors de la récupération technique de votre machine grâce àIntegra Metering AG (formerly Aquametro) des produits.

Produits de marque Integra Metering AG (formerly Aquametro)

80113

aqua pulse 1l; System module pulse Pulse value: 1 liter Pulse width: 50 ms Switching capacity: max. 220 mA, 48 V DC Cable length, fixed: 1.5 m Supply: 3 V lithium battery Battery life: 15 years Re-running detection with compensation Degree of protection: IP 68

80113 aquapuls 1 l

System module aquapuls ®For Updating of aquabasic ® cold water meters.Pulse is 1 l / pulse with return compensation.Switching capacity 220 mA/48 VDC. IP 68with 1.5 m cable, securely mounted. With battery power

80522.

Modbus communication modul for alec ST

80695

[M-Bus Mini-Master USB - M-Bus Pegelwandler Mobiler M-Bus Pegelwandler mit USB-Schnittstelle, - Integrierte M-BUS Spannungsversorgung (32 M-Bus Lasteinheiten) - Zwei LED zur Anzeige des Datenverkehrs in Sende- und Empfangsrichtung - Schutz gegen Überstrom und Kurzschluss auf dem M-Bus - Versorgung aus der USB-Schnittstelle, keine externe Speisung nötig]

81152

VSR 32 1 1 / 4'' OR Klinger Sil; Fittings DN 32 Fittings R 1 1/4 " Union nuts G 1 1/2 " without boundary (brass) with seals

81153.

VSR 40 1 1/2 '' OR Klinger Sil; Fittings DN 40 Fittings R 1 1/2 " Union nuts G 2 " without boundary (brass) with seals

83099 ARD 25/3315-G6

Anneau piston Durchflussm. DOMINO compteurs à piston rotatif - boîtier en acier inoxydable, les brides DIN 2501 - la chambre de mesure en acier inoxydable - graphite de segment de piston - Joints PTFE / Variseal

83565 IN0,1H/RW/RD 25

ARD Construction Group DOMINO® - Reguliergetriebe - pulseur pour des températures élevées NAMUR / DIN 19234 - Rouleau 6 chiffres, pouvant tourner. - bague de verrouillage avec couvercle

89206 TOPAS PMW - OBSOLETE

Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls

89216,TOPAS PMW - OBSOLETE

Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls water meter

89224 TOPAS PMWF - OBSOLETE

Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls

89244 TOPAS PMWF - OBSOLETE

Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls

89252 TOPAS PMWF - OBSOLETE

Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls

89270;TOPAS PMWS - OBSOLETE

Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls

89629 TOPAS PMG - OBSOLETE

Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls

89642 TOPAS PMGS - OBSOLETE

Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls

89654 TOPAS PMGF - OBSOLETE

Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls

89771 VZO 8 OEM-RE0,0125

(CONTOIL ® fuel oil meters Reed pulser Pulse value 12.5 ml Nominal diameter: 8 mm With female thread for Kupferrohrverschr. 1/4 " Nominal pressure: PN 25 Maximum permissible temperature: 60 ° C Mounting position: horizontal / vertical Largest flow Qmax. 200 l / h In continuous operation: 135 l / h Error of measurement: 4-200 l / h ± 1% of measured value Pulse value: 0.0125 l)

92047 VZO 20 RC 130/16

VZO 15... 40 avec filetage, PN 16

92049 VZO 20 FL 130/25

Fuel-oil fuel meter

93533

[AMBUS IS M-Bus Impulssammler 1 Impulseingang 2 Leiter M-Bus Schnittstelle 2 Leiter Energieversorgung aus AMBUS ZS oder Net]

94249

PMG 32-RH1 6.0_260_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0,075 m³ / h Continuous flow qp: 6 m³ / h Maximum flow qs: 12 m³ / h Kvs-value: 12.7 m³ / h Pressure loss at qp: 0,22 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004

94252 PMGF 32-RH1 5.0-150-1 1/4"

Size: DN 32 with thread 1 1/2 "(for screw 1 1/4") Nominal pressure: PN 16 bar length: 150 mm Mounting position: vertical falling temperature max .: 130 ° C Maximum flow qs: 6.3 m3 / h Nominal flow qp: 5 m3 / h minimum flow qi: 0.1 m3 / h pulse value: 1 l Smallest readable amount: 0.1 l registrable: 99,999 m3 measuring principle: multi-jet impeller, dry running With CE marking

94255

PMGS 32-RH1 5.0_150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical ascending Riser counter Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0.1 m³ / h Continuous flow qp: 5 m³ / h Maximum flow qs: 6,3 m³ / h Kvs-value: 13.6 m³ / h Pressure loss at qp: 0,14 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004

94525 50 50-200

MeiStream RUBIN Kaltwasserzähler Nenngrösse: DN 50 Flanschanschluss: EN 1092-1 Nenndruck: PN 16 bar Baulänge: 200 mm Einbaulage: horizontal/vertikal Schutzart: IP 68 Temperatur max.: 50°C Überlastungsdurchfluss Q4: 90 m3/h Dauerdurchfluss Q3: 50 m3/h Übergangsdurchfluss Q2: 0.4 m3/h Kleinster Durchfluss Q1: 0.15 m3/h Kleinste ablesbare Menge: 0.5 l Registrierfähigkeit: 1 Mio m3 Messprinzip: Woltman-Turbine Messbereich Lieferkennzeichnung: R 100

Contactez-nous pour une demande